Voltage Monitoring Relays
Single Phase Current Monitoring Relays
Earth Fault Relays
Frequency Monitoring Relays
Earth Leakage Relays
Reverse Power Relay

Monitoring Relays

Voltage Monitoring Relays
Frequency Monitoring Relays
Power Monitoring Relays & CBCT
Special Function Timers
Multifunction Timer
Conductive Liquids
Non Conductive Liquids
Alternating Relay
Liquid Level Controllers
Level Controllers – Conductive Liquids
Level Controllers – Non Conductive Liquids
Booster Pump Controller
Twin AC Controller
Process/Plant Control and Automation
Twin AC Controller
Most compact alarm Annunciator with improved window design and all major features of MBAS 0600 Annunciator. Models with built-in Buzzer & Push buttons also available.

Technical Data

  • Supply Voltage 90 to 270 VAC/DC
    24 VDC /30 VDC /48VDC
  • Supply Frequency [FOR AC]50 / 60 Hz ± 3%
  • Windows4 / 6 / 7 / 8 [max]
  • Display (Window)Window lenses replaceable Legends replaceable.
    Window Dimensions
  • Small 17 X 37 mm
  • Big 27 X 37 mm. for 4 Windows model only
  • Power Consumptions1.5 Watts per Window (Max)
  • Flash Rate50 - 60 Flash per min. in fast flashing
    20 - 30 Flash per min. in slow flashing
  • Operating SequenceS1, S2, S3, S4 (Site Selectable)
  • Other FeaturesNO / NC and Grouping (Trip/Non trip) Selection
    Supervisory Contact output.
  • Optional FeaturesAny other operating sequence
    RS485 Output
  • Input SignalPotential Free contacts
  • Input Interrogation Voltage+12 VDC
  • LED Colour in WindowsRed, Green, Yellow, Amber, Blue, White.
  • Output Contacts1 NO + 1 NO [For Hooter]
    1NO For Ring back or Supervisory contact (Optional)
  • Output Contact Rating5 Amp, 240V AC (Resistive)
  • Inbuilt Push Buttons4 NOS. (Test, Mute, Accept, Reset) Membrane type (Optional)
  • CommunicationRS485 (MODBUS RTU/ASCII) (Optional)
  • Operational Temp. Limit-5°C to 60°C
  • HumidityUpto 95% Rh
  • EnclosureABS moulded enclosure
    Unit Dimensions
  • Overall (L x W x D)96 x 96 x 76 mm
    96 x 96 x 137 mm (for 12 V DC Supply Model)
  • Cutout (L x W)92 x 92 mm
  • Weight550gm
PROGRAMMING OF MBAS 08
SR. NO. KEY OPERATION MODE OF OPERATION WINDOW STATUS WDL STATUS
1 --- Normal Run Mode As per operation Flashing @ 1 flash/sec.
2 TEST + ACK
Pressed (for 5 Sec.)
Sequence selection Windows
fast flashes for
2 to 3 sec.
W1 - ON - S1
W2 - ON - S2
W3 - ON - S3
W4 - ON - S4
Flashing @ 1 flash/sec.
3 TEST + ACK
Pressed (for 5 Sec.)
NO / NC selection W - ON - NO
W - OFF- NC
Off
4 TEST + ACK
Pressed (for 5 Sec.)
Grouping selection W - ON - Group 1
W - OFF- Group 2
Steady On
5 TEST + ACK
Pressed (for 5 Sec.)
Device ID selection As per chart in Manual Fast Flashing
6 Auto exit after 5 Seconds