Voltage Monitoring Relays
Single Phase Current Monitoring Relays
Earth Fault Relays
Frequency Monitoring Relays
Earth Leakage Relays
Reverse Power Relay

Monitoring Relays

Voltage Monitoring Relays
Frequency Monitoring Relays
Power Monitoring Relays & CBCT
Special Function Timers
Multifunction Timer
Conductive Liquids
Non Conductive Liquids
Alternating Relay
Liquid Level Controllers
Level Controllers – Conductive Liquids
Level Controllers – Non Conductive Liquids
Booster Pump Controller
Twin AC Controller
Process/Plant Control and Automation
Twin AC Controller

Power Line Transducers And Multifunction Meter

D1 PTC3 / D1 PTV3

    D1 PTC3
  • 2 Wire Current transducer
  • Input AC Current
  • Output (DC) single
  • Accuracy 0.5%
    D1 PTV3
  • 2 Wire Voltage transducer
  • Input AC Voltage
  • Output (DC) single
  • Accuracy 0.5%
Operations
The Transducer converts the A.C. Input current or Voltage signal to a 4-20mA D.C. Output. The output is directly proportional to the input signal. 2 Wire Transducer obtain the power to operate from the 4-20mA output circuit to which they are connected, and therefore require no separate auxiliary supply. It is average sensing RMS calibrated current Transducer. 2 Wire Transducers have an advantage over conventional auxiliary powered transducer, because no separate auxiliary is required, savings in the cost of providing a separate auxiliary supply and wiring are made. The above Transducer can be used to measure current or voltage in energy management systems, switchboards, generator and telemetry controls. Isolation of 2 KV is provided between the input and output signal, allowing the output to be fed to conventional analogue meters, digital meters, PLC, and computer systems.
    Supply Voltage
  • Auxiliary Supply 7.5 - 36 V DC, 2 Wire Type (Mostly 24 V DC)
  • Power ConsumptionLess than 1 VA
  • SensorN.A.
    Input Value
  • I in0 – 1 A / 0 – 5 A AC for D1 PTC3
  • V in0 – 150 V, 0 – 300 V, 0 – 500 V AC or any user range for D1 PTV3
  • Resistance Type N.A.
  • DC Output (Single / Dual) 4 - 20 mA DC
  • No of Signal Output Single
  • Response Time Less than 500 mSec.
  • Input / Output Isolation 2 KV 50 Hz for 1 min.
  • Temperature 0 – 55°C.
  • Humidity 95% RH Non-condensing
  • Accuracy (+/-)0.5% of Span
  • Enclosure D1
  • Dimensions (L x W x D) (mm) 30 X 80 X 120
  • Weight 100 gms.
    Suitable for Panels in Following Apllications :
  • MCC Panel
  • Metering Panel