Voltage Monitoring Relays
Single Phase Current Monitoring Relays
Earth Fault Relays
Frequency Monitoring Relays
Earth Leakage Relays
Reverse Power Relay

Monitoring Relays

Voltage Monitoring Relays
Frequency Monitoring Relays
Power Monitoring Relays & CBCT
Special Function Timers
Multifunction Timer
Conductive Liquids
Non Conductive Liquids
Alternating Relay
Liquid Level Controllers
Level Controllers – Conductive Liquids
Level Controllers – Non Conductive Liquids
Booster Pump Controller
Twin AC Controller
Process/Plant Control and Automation
Twin AC Controller

Power Line Transducers And Multifunction Meter

D2 PTV1

Voltage transducer

Input AC voltage

Output (DC) single or dual

Accuracy 0.5%

Operations
The input Voltage signal is scaled down through Interposing potential transformer. The scaled down signal is fed to a precision rectifier stage, its output is processed to provide DC Voltage / Current output proportional to input AC voltage. The output signal is calibrated for RMS value.

Technical Data

    Auxiliary Supply
  • Auxillary 18 - 60 / 24/48 VDC +/- 20%, 80-300 VAC / DC, 50 Hz
    Power Consumption
  • Power Consumption 3.5 VA - AC, 4 VA - DC 24/48 VDC +/- 20%
    Input Value
  • I inNA
  • V in63.5 / 110 / 240 / 415 V
    DC Output (Single / Dual)
  • DC Output (Single / Dual) 0 - 1 mA, 0 - 10 mA, 0 - 20 mA, 4 - 20 mA, 0 - 5 V, 0 - 10V DC Other optional on request
    No of Signal Output
  • No of Signal Output Single (Optional Dual Output)
    Response Time
  • Response Time Less than 500 milliseconds
    Input / Output isolation
  • Input / Output isolationGalvanic
    Temperature
  • Temperature 0°C to + 55°C
    Humidity
  • Humidity Up to 95% Rh non condensing
    Dimensions (L x W x D) (mm)
  • Dimensions (L x W x D) (mm) 75 x 56.5 x 117.5
    Weight
  • Weight 440 gms

    Common Specifications

    Output Load Resistance (Rout)
  • For Current Output Max. 10V/I out (Optional Max. 15V/Iout)
  • For Voltage Output10 Kohm (min.)
    Output Ripple
  • Output Ripple Less than 0.5% of span (peak to peak)
    Auxiliary Supply Burden
  • Auxiliary Supply Burden Less than 4 VA
    Insulation Resistance
  • Insulation Resistance More than 100 Mohms at 500 V DC
    Zero Span Adjustment
  • Zero Span Adjustment Optionally provided
    Terminals
  • TerminalsSuitable for 2.5 sq.mm wires
    Enclosure Type
  • Enclosure Type ABS Plastic, Ingress Protection IP40
    IEC Standard
  • IEC Standard60688

Applications

Generator Panels

Motor Control Panels

CONTACT