Home  |  Contact Us

banner_phase_failure_relays


 
Products I Products For Agro Sector I F3 PGA1



F3 PGA1
Autoswitch with dry run protection
Auto reset for phase failure faults & manual reset for dry run
Auto/Manual switch.
1 CO output contact.
20 Amps.
Inbuilt CT.
Indications Relay ON Green, Dry run Red
Supply Voltage : 200 - 450 VAC, 50 Hz ± 3%

Output Relay Contact : 1 CO

Output Contact Rating :
5 Amp, 240 VAC (RESISTIVE)

Unbalance Trip Setting : 50 V ± 10 VAC

Trip Time Delay
For unbalance
: 4 Sec ± 2 Sec

Dry Run Setting : 50% (±10%) of set current

On Time Delay : 1 Min (In Auto mode)

Star-Delta Changeover Time Delay : N.A.

Resetting : Auto for SP/UB/RP & Manual Reset for Dry run

Auto Switch : Present

Enclosure : (D2-03) ABS

Dimensions (mm)
Overall ( H x W x D )
Mounting
:
:
76 x 56.5 x 117.5
67 x 46

Mounting : Flush Mounting

Weight : 350gms

Level sensor
Quantity
Dimensions
:
:
-
-

Operating Conditions
Temperature
Humidity
:
:
-5 °C TO + 60 °C
Upto 95% Rh
Electrical Connection Diagram

F3 PGA1
Submersible Pumps
Pump sets at Farms, Rivers, and Wells
Supply Voltage 3ph. 250 V- 500V AC
Agricultural Pump DOL Starters
 
 
 
 



Products For Agri Sector